Back to top
Polarimeter laurents Half Shade
Polarimeter laurents Half Shade

Polarimeter laurents Half Shade

Polarimeter laurents Half Shade Specification

  • Feature
  • High precision optical rotation measurement
  • Model No
  • Laurent Half Shade
  • Measurement Range
  • 0° to ±180°
  • Accuracy
  • ± 0.05 degree
  • Core Components
  • Half shade device, polarizer, analyzer, scale, observation tube
  • Automation Grade
  • Manual
  • Power Source
  • Manual
  • Capacity
  • Standard tube length 200 mm
  • Temperature Range
  • Ambient (non-temperature controlled)
  • Equipment Materials
  • Optical glass, metal, brass and aluminum parts
  • Type
  • Laurents Half Shade Polarimeter
  • Usage
  • Measurement of optical rotation, analysis of sugar solutions / substances
  • Display Type
  • Analog scale
  • Dimension (L*W*H)
  • Approx. 400 mm x 150 mm x 185 mm
  • Weight
  • Approx. 4.5 kg
  • Finish
  • Powder coated for durability
  • Lamp Source
  • Sodium lamp (optional accessory)
  • End Window
  • Glass, removable for tube filling
  • Eyepiece
  • Adjustable for clear viewing
  • Optical Filters
  • Included
  • Magnifier
  • Provided for precise scale reading
  • Observation Tube
  • Calibrated
  • Packing
  • Fitted in a sturdy wooden case
  • Scale Graduation
  • 0.05
  • Rotating Mechanism
  • Smooth rotation with knurled knob
 
 

About Polarimeter laurents Half Shade

Consists of Laurent half shade, polariser, analyzer, brass scale graduated from 0 to 3600 or 0-1800 with vernier reading 6" and accommodates a 200mm. glass tube.It is packed in a card board box.



Precision at Its Core

This Laurent Half Shade Polarimeter is engineered for high accuracy in optical rotation measurements, thanks to a finely graduated analog scale (0.05) and a robust half shade optical system. Whether youre analyzing sugar solutions or testing other substances, the adjustable eyepiece and included optical filters offer clear and precise readings every time.


Durability Meets Convenience

Crafted from premium materials and finished with a durable powder coating, this polarimeter stands up to frequent use in laboratories. Its design features, such as a removable glass end window for easy filling and a smooth knurled knob for rotation, make maintenance and operation straightforward. A sturdy wooden case ensures safe storage and transportation.


Versatile and User-Friendly

With a standard 200 mm observation tube and compatibility with sodium lamps (sold separately), this instrument accommodates a range of experimental needs. Simple manual controls and an analog display allow users of all experience levels to confidently achieve reproducible results in both academic and industrial settings.

FAQs of Polarimeter laurents Half Shade:


Q: How does the Laurents Half Shade Polarimeter measure optical rotation?

A: This polarimeter measures optical rotation using a half shade device, where the sample tube and analyzer enable the user to determine the angle of rotation by aligning the visual field. The reading, indicated on a finely graduated analog scale, reflects the optical activity of the tested substance.

Q: What substances can be analyzed with this polarimeter?

A: The device is primarily used for measuring optical rotation in sugar solutions, but it is also suitable for other optically active substances, making it valuable for laboratories in the food, chemical, and pharmaceutical industries.

Q: When should I use the optical filters and magnifier provided?

A: Optical filters are used to enhance contrast and accuracy when observing samples, especially under varying lighting conditions. The magnifier is ideal for precise reading of the 0.05 graduated scale, ensuring measurement accuracy during sensitive analyses.

Q: Where is the best place to use this polarimeter?

A: It is best operated in laboratories or educational settings where temperature is maintained at ambient levels. Its manual operation and sturdy design make it suitable for both academic and industrial environments that require high-precision measurements.

Q: What benefits does the powder-coated finish provide?

A: The powder-coated finish enhances the polarimeters resistance to corrosion and wear, extending its service life and maintaining a professional appearance, even with heavy laboratory use.

Q: How do I fill the observation tube?

A: The polarimeter features a removable glass end window, allowing the user to easily open, fill, and reseal the tube for each sample, simplifying sample preparation and reducing the risk of spillage.

Q: What is the measurement range and accuracy of this polarimeter?

A: The analog scale measures from 0 to 180 with a high degree of accuracy (0.05), making it well-suited for applications demanding precise determination of optical rotation.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in PHYSIC RESEARCH INSTRUMENTS Category

Magnet Horse Shoe

Magnet Horse Shoe

Price 120 INR

Minimum Order Quantity : 50 Pieces

Feature : Ushaped design for high magnetic strength

Usage : Industrial Educational Demonstrations

Weight : 50 Grams (g)

Model No : HS100

Lamp  Scale

Lamp Scale

Feature : Precise measurement

Usage : Lab Experiments

Weight : Lightweight

Model No : LS100

Traveling Microscope

Traveling Microscope

Price 4800 INR

Minimum Order Quantity : 10 Units

Feature : Precise Measurement Compact Design

Usage : Laboratory Educational

Weight : Approx. 3 kg

Model No : TM01

Slotted Weight Brass

Slotted Weight Brass

Feature : Slotted design with interlocking weights

Usage : Laboratory and educational purposes

Weight : Varied slotted weights

Model No : SWB001