Back to top
Copper Voltameter
Copper Voltameter

Copper Voltameter

Copper Voltameter Specification

  • Accuracy
  • High accuracy for electrochemical experiments; 1% on mass deposited
  • Model No
  • CV-60
  • Voltage
  • Operates typically at 2-6V DC
  • Power Source
  • External DC supply (not included)
  • Automation Grade
  • Manual
  • Feature
  • Durable build, easy electrode removal, corrosion resistant, laboratory-grade
  • Frequency
  • 50-60 Hz
  • Capacity
  • 500 ml (typical), customizable as per requirement
  • Measurement Range
  • 1-500 mA (Current, depending on supply)
  • Temperature Range
  • Ambient to 60C
  • Core Components
  • Glass jar, copper electrodes, mounting lid, wiring terminals
  • Equipment Materials
  • High quality glass jar, pure copper plates, metal stand, insulated terminals
  • Type
  • Copper Voltameter
  • Usage
  • Measurement for electrolysis and Faradays Law verification
  • Display Type
  • Analog
  • Dimension (L*W*H)
  • Approx. 17 x 7 x 20 cm
  • Weight
  • Approx. 500-800 grams (varies with kit configuration)
  • Glass Type
  • Chemically resistant, laboratory grade
  • Number of Electrodes
  • 2 Pure Copper Plates
  • Compliance
  • Meets general laboratory quality standards
  • Mounting
  • Removable electrode holder/lid
  • Finish
  • Smooth, clear glass
  • Application
  • Physics and Chemistry lab experiments
  • Terminal Type
  • Brass screw/knurled for secure connection
  • Electrode Dimensions
  • Approx. 70mm x 25mm x 1mm
  • Cleaning
  • Easy-to-clean removable parts
 

Copper Voltameter Trade Information

  • Payment Terms
  • Cash in Advance (CID), Cheque, Cash Advance (CA)
  • Delivery Time
  • 1 Months
  • Sample Available
  • Yes
  • Sample Policy
  • Contact us for information regarding our sample policy
  • Main Export Market(s)
  • Australia, Middle East, Western Europe, Africa, Central America, Eastern Europe, South America, Asia, North America
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001 2015
 

About Copper Voltameter

We are a recognized name in the market for manufacturing and supplying Copper Voltameter. The provided instrument is manufactured at our in-house production unit by our seasoned professionals using quality-approved basic materials with the aid of the modern methodology. The offered instrument is well-suited for use in various physics experiments for measuring the quantity of passing electricity and strength of current in a conductor. Apart from this, our clients can avail this Copper Voltameter from us in various specifications at rock-bottom prices.

Features:

  • Safe to use

  • Resistant to adverse laboratory effects

  • Excellent performance

  • Accurate measuring



Precision Laboratory-Grade Voltameter

Engineered for repeatable electrochemical measurements, the CV-60 Copper Voltameter delivers high-accuracy verification of Faradays Law for classrooms and laboratories. It employs robust, pure copper electrodes and laboratory-grade glass, ensuring reliable performance in routine as well as advanced experiments. Its smooth, clear finish and modular design facilitate efficient maintenance and extended lifespan.


Customizable and User-Friendly Design

This voltameter is crafted to be both practical and adaptable. With customizable capacity, removable electrode holders, and easy-to-clean components, users benefit from hassle-free setup and cleaning. Secure brass terminals guarantee a steady connection during operation, and the voltameter seamlessly integrates into standard laboratory setups.

FAQs of Copper Voltameter:


Q: How is the Copper Voltameter set up before starting an experiment?

A: Begin by securely mounting the two pure copper plates into the removable electrode holder, then fit them into the glass jar filled with a suitable electrolyte. Attach wires to the brass screw terminals for a firm connection, connect to an external 2-6V DC power supply, and ensure the setup is stable before commencing electrolysis.

Q: What measurements can be performed with the CV-60 Copper Voltameter?

A: The voltameter accurately measures current (1500 mA) and mass of copper deposited during electrolysis. It is widely used to verify Faradays Laws in chemistry and physics labs for understanding electrochemical deposition and quantitative analysis of charge transfer.

Q: When should the electrodes or electrolyte be replaced during usage?

A: Electrodes and electrolyte should be replaced whenever visible corrosion, contamination, or diminished conductivity is observed, or after several cycles to maintain experiment accuracy. Regular inspection before each use ensures reliable results and optimal performance.

Q: Where is the best place to use and store the voltameter?

A: The voltameter is designed for laboratory environments, preferably on stable, vibration-free surfaces close to a DC power supply. Store the device in a clean, dry area away from direct sunlight and corrosive substances, ensuring all removable parts are thoroughly cleaned and dried after use.

Q: What is the process for cleaning and maintaining this Copper Voltameter?

A: Detach the removable electrode holder and separate the copper plates and terminals. Clean each component with mild laboratory-grade cleaners, rinse thoroughly, and dry completely before reassembly. Regular cleaning after each experiment prolongs the units durability and measurement precision.

Q: How does using the CV-60 benefit physics and chemistry experiments?

A: The device offers reliable, repeatable results and high accuracy (1% on mass deposited), making it invaluable for teaching electrochemical principles and validating theoretical predictions. Its robust construction and ease of use also promote efficient experimental workflows in educational and research settings.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in CHEMISRTY EQUIPMENTS Category

Compressor Unit For Flame Photometer

Compressor Unit For Flame Photometer

Price 29000 INR / Piece

Minimum Order Quantity : 1 Piece

Power Source : Electric

Voltage : 220V

Usage : Used for flame photometric analysis in laboratories

Model No : FP49

Magnetic Stirrer

Magnetic Stirrer

Price 1550 INR / Piece

Minimum Order Quantity : 1 Piece

Power Source : Electric

Voltage : 220V

Usage : Laboratory Mixing and Heating

Model No : MS101

DIAPHRAGM TYPE Vaccum Pump

DIAPHRAGM TYPE Vaccum Pump

Power Source : Electric

Voltage : 220240V

Usage : Industrial Laboratory applications

Model No : GenericModel123

Kari Fisher Titri Meter

Kari Fisher Titri Meter

Power Source : AC/DC Adapter or Battery Operated

Voltage : 220V

Usage : Laboratory Water Analysis, Industrial Use, Educational Institutes

Model No : KFTM101